Check valve selection and installation
2015-06-23 14:58:51Have read3043

The check valve is also called or a one-way valve, its role is to prevent the backflow medium pipeline.The bottom valve of the pump suction also belong to the check valve class.

Open-close part by medium flow and power to open or closed, to prevent the backflow medium valve check valve.Check valve belong to automatic valve class, mainly for the one-way flow of medium pipeline, only allowed to medium flows in one direction, in order to prevent accidents.

A, the selection of check valves:

1, check valve, generally applies to clean medium, should not be used for medium containing solid particles and viscosity is bigger.

2, for low pressure under DN50mm check valve, appropriate chooses butterfly check valve, vertical lift check valves and diaphragm type check valve;For DN is greater than 200 mm, less than 1200 mm in the low pressure check valve, appropriate chooses no wear spherical valve last time;For DN is greater than 50 mm, less than 2000 mm of low pressure check valve, appropriate chooses butterfly check valves and diaphragm type check valve.

3, the diaphragm type check valve is suitable for easy to produce water piping, the diaphragm is a good way to eliminate medium counter-current when the water, but restricted by temperature and pressure, commonly used on low pressure pipe at room temperature

4, for closing the water impact is small or no water pipe, appropriate chooses slowly-closing swing check valve gentle butterfly check valve is closed.

Second, the construction and installation of check valve

1, installation position and height, import and export direction must comply with the design requirements, pay attention to the medium flow direction should be consistent with the body the direction of the arrow, the connection should be firmly connected

2, a visual inspection must be conducted before installation of valve, the valve nameplate should be consistent with existing national standards "universal signal valve" GB 12220.For the working pressure is greater than 1.0 MPa and valve with the function of cutting off on ZhuGanGuan, strength and strict performance test should be done before the installation, qualified rear must use.Strength test, the test pressure is 1.5 times the nominal pressure, duration of not less than 5 min, shell and packing shall be no leakage of valve shall be qualified.Leak test, the test pressure is 1.1 times the nominal pressure;The duration of the test meet the requirements of GB 50243.

3, do not make the check valve in the line to bear weight, large check valve shall be independent support, make it not influenced by the pressure caused by the piping.

3, check the installation notice:

1, do not make the check valve in the line to bear weight, large check valve shall be independent support, make it not influenced by the pressure caused by the piping.

2, when installation, pay attention to the medium flow direction should be consistent with valve body by the ticket direction arrow.

3, vertical elevating disc check valve should be installed in vertical pipe runs.

4, elevating disc check valve should be installed in horizontal pipe runs.

 